High voltage vacuum circuit breaker ZN85-40.5 kV
High-voltage SF6 circuit breaker for outdoor installation type LW36-40.5

High-voltage SF6 circuit breaker for outdoor installation type LW36-40.5

Outdoor high-voltage SF6 circuit breaker LW36-40.5/1250A-2000A is a high-voltage electrical equipment for outdoor installation of three-phase alternating current 50Hz.

Outdoor high-voltage SF6 circuit breaker type LW36-72.5 126

Outdoor high-voltage SF6 circuit breaker type LW36-72.5 126

The high-voltage autogas SF6 circuit breaker LW36-72.5/126(G) is designed for use in AC power systems with a frequency of 50 Hz and a voltage of 110 kV.

High voltage SF6 circuit breaker LW36-252 kV

High voltage SF6 circuit breaker LW36-252 kV

The LW36-252 high-voltage autogas gas circuit breaker is designed for use in AC power systems with a frequency of 50–60 Hz and a rated voltage of 252 kV.

High voltage vacuum circuit breaker ZN63A(VS1)-12

High voltage vacuum circuit breaker ZN63A(VS1)-12

The VS1-12 indoor high-voltage vacuum circuit breaker (also known as ZN63A-12) is designed for use as a complete indoor switchgear in 50 Hz AC power networks with a voltage of 3-10 kV.

High voltage vacuum circuit breaker ZN85-40.5 kV

High voltage vacuum circuit breaker ZN85-40.5 kV

The high-voltage vacuum circuit breaker for indoor installation ZN85-40.5 (hereinafter referred to as the circuit breaker) is intended for use in three-phase alternating current electrical power systems with a frequency of 50 Hz and a rated voltage of 40.5 kV.

High voltage vacuum circuit breaker ZW32-33F

High voltage vacuum circuit breaker ZW32-33F

The ZW32-33F series outdoor high voltage vacuum circuit breaker is designed for use in 50Hz AC three-phase electrical systems with a rated voltage of 33kV for switching load current, overload current and short-circuit current.

High voltage vacuum contactors CKG3 and 4 series

High voltage vacuum contactors CKG3 and 4 series

This series of high-voltage vacuum contactors is intended for use in AC electrical networks with a frequency of 50–60 Hz with a rated main circuit voltage of 7.2 (12) kV and a rated current of 160 A to 1600 A.

CKJ5 Series Low Voltage Vacuum Contactor

CKJ5 Series Low Voltage Vacuum Contactor

This series of vacuum contactors is designed for use in AC electrical networks with a frequency of 50–60 Hz with a rated main circuit voltage of up to 1.6 kV and a rated current of 160 A, 250 A, 400 A and 630 A.

CKJ20 Series Low Voltage Vacuum Contactor

CKJ20 Series Low Voltage Vacuum Contactor

This series of vacuum contactors is designed for use in AC electrical networks with a frequency of 50–60 Hz with a rated main circuit voltage of up to 2 kV and a rated current of 160 A, 250 A, 400 A, 630 A, 800 A, 1000 A to 1250 A.

<<<123456>>> 4 / 7

Products

The company is a large group of enterprises in the field of power equipment, covering a series of high-voltage and low-voltage vacuum contactors for 0.4–40.5 kV, pole vacuum circuit breakers, SF6 load switches, reactive power compensation devices, metering devices, specialized disconnectors and circuit breakers for power plants of 40.5 kV / 72.5 kV / 110 kV / 220 kV, high and low voltage switchgear, as well as operation and maintenance services for energy facilities.

Home
Products
About Us
Contacts

Пожалуйста, оставьте нам сообщение

Privacy Policy

Thank you for using this site (“we”, “us” or “our”). We respect your rights and interests in personal information, comply with the principles of legality, legitimacy, necessity and integrity, and protect your information security. This policy describes how we process your personal information.

1. Collection of information
Information that you provide voluntarily, such as name, mobile number, email address, etc., is completed during registration. Information such as device model, browser type, access logs, IP address, etc. is automatically collected to optimize service and security.

2. Use of information
provide, maintain and optimize website services;
account verification, security protection and fraud prevention;
Send necessary information such as service notifications and policy updates;
Comply with laws, regulations and applicable regulatory requirements.

3. Protection and exchange of information
We use security measures such as encryption and access controls to protect your information and only store it for the minimum period necessary to complete the task.
Do not sell or rent personal information to third parties without your consent; Share only if:
Get your explicit permission;
third parties entrusted to provide services (subject to confidentiality obligations);
Respond to legal requests or protect legitimate interests.

4. Your rights
You have the right to access, correct and supplement your personal information, and you can also apply to cancel your account (after cancellation, the information will be deleted or anonymized according to the rules). To exercise your rights, you may contact us using the contact details provided below.

5. Policy Updates
Any changes to this policy will be notified by posting on the site. Your continued use of the services means your acceptance of the amended rules.